labindia logo
Labindia Analytical Top Quality Manufacturer of Tablet Hardness Tester TH - 1050 M

Tablet Hardness Tester | Single Station TH-1050M

Tablet Hardness tester (TH - 1050M) tablet hardness tester comes with alphanumeric splash waterproof polyester soft keys for keyboard and is equipped with user-interactive software in dialogue mode for the ease of operations. This tablet hardness tester is a perfect entry level model for manual testing of the tablet physical properties. All the five parameters like Thickness, Length, Diameter Hardness and Width can be measured simultaneously.

There is a built in clock and facility for date and time display in Tablet hardness tester TH - 1050M. Automatic run can be performed continuously for upto 99 tablets. Complying to the Pharmcopeias of US/EP/BP/IP.

Get Quote
Get Quote

X
Request Demo
Request Demo
X
Call Now
Standard Features of Hardness Tester TH 1050 M
  • Advance Micro-controller based user-friendly state-of-the-art product design with alphanumeric splash waterproof polyester soft keys for keyboard. User interactive software in dialogue mode for ease of operation with protection against invalid entries.
  • Single Station Automatic measurement of tablet parameters - Thickness, Width, Diameter/Length, Hardness and Weight
  • Non-Volatile memory storage of 99 methods with parameters with Alphanumeric entries of Sample Name and Identification Number for authentication. 
  • Automatic run can be performed continuously up to 1-99 tablets. RUN can be re-started on power failure or on System Reset with last run parameters 
  • Linear Displacement 0.2, 0.4, 0.6, 0.8, 1.0, 1.2, 1.4, 1.6 mm/sec with fast advance & return movement of breaking arm saves runtime. 
  • Daily Auto Incremented Run Number and Factory entered CUSTOMER NAME with Instrument Serial Number on report makes system foolproof and GLP compliant. 
  • Two Tier - a) ADMIN, and b) USER password protection for method editing and Validation. 25 Users can be set with Name and password. 
  • Built-in Real Time Clock (RTC) for date and time display and on printout.
  • Process Stage and Compression Press no. entry, NMT, NLT and Percentage Limit for detected values of Width, Thickness, Diameter/Length & Hardness with Star mark for out of limit values.
  • Validation/Calibration protocol with verification for Hardness - 3 point Load Cell calibration with Standard weights & Diameter/Length/Thickness/Width Calibration with Standard gauges. 
  • Quick RUN for Independent Thickness, Diameter/Length, Hardness or All parameter measurement in sequence up to 25 sample tablets with GLP information. 
  • Error indication on display with Audible alarm helps user to trace the problem. 
  • Printer Compatibility for Deskjet, Inkjet & Dot-matrix printer. 
  • PC Based Data downloading facility using EDC 21 software over LAN (optional)
Typical Specification

 

Control

Micro-controller based (Advanced version of microprocessor)

Keyboard

Alphanumeric splash waterproof polyester soft keys.

Display

40 x 2 line back lighted liquid crystal display (LCD)

Test Parameter: No. of Tablets = 1 - 99.

 

 

Thickness

 

Measuring Sensor - Linear Transducer

Measuring Range - 0.1mm to 15.0mm.

Measuring Unit - mm or inch.

Measuring Accuracy - Better than ± 0.06mm.

 Width

Measuring Sensor - Stepper controlled Load Touch sensed

Measuring Range - 1.0 mm to 15.0mm

Measuring Unit - mm or inch

Measuring Accuracy - Better than ± 0.06mm.

Diameter/Length

Measuring Sensor - Stepper controlled Load Touch sensed

Measuring Range - Diameter 0.1mm to 25.0mm

Length 0.1mm to 40.0mm (optionally up to 65mm i.e. 25.01 mm to 65.00 mm option available suitable for Bolus Tablets)

Measuring Unit - mm or inch

Measuring Accuracy - Better than ± 0.06mm.

4. Hardness: Speed Control by Stepper motor

Linear Displacement Range 0.2, 0.4, 0.6, 0.8, 1.0, 1.2, 1.4, 1.6 mm/sec with fast advance and return of breaking arm.

Measuring Sensor - Load Cell - Strain gauge

Measuring Range - 2N to 500 N. (600N - Optional)

Measuring Unit - N (Newtons) / Kp (Kilo Ponds) / Kgf Sc (Strong Cobb) / Lbs / Pound.

Measuring Accuracy - ± 1N / ± 0.1 KP

Weight:

Manual Entry by User (for reporting purpose)

Automatic Balance Inter face - Sartorius / Mettler when Automatic Wt. Transfer option is selected.

Method Storage

99 programs with parameters.

Data Storage

Available with Non-Volatile memory.

Report Format   

 a) GLP & Pharmacopoeia compliant repor t with Statistics   (Avg, Min, Max and RSD)

 b)  Program parameter Report.

 c)  Validation Reports

 

 

Output

 a)  Centronics parallel port for Dot matrix / Desk jet Printer.

       b) RS232 C ports for

 i) Balance connectivity (Sar torius/Mettler)

ii) PC Connectivity for Data Download

Instrument weight

10 kgs.

Dimensions

314W x 200H x 330D mm.

Power

110 / 230Vac, ± 10%, 60 / 50 Hz, 50W option available.

 

 Environmental Operating Conditions

a) Operation: Indoor.

b) Temperature: Ambient to 45°C.

c) Humidity: 5 to 90% non-condensing.

d) Altitude: Upto 2000m.

 